최신Citrix NetScaler 10 Essentials and Networking - 1Y0-350무료샘플문제
문제1
Scenario: An engineer needs to configure a monitor to ensure that each server is tested every 10 seconds and requires that the server pass the test four consecutive times before marking a server as UP. If the test fails, the server should be marked as down for 60 seconds.
To configure the monitor, the engineer should configure an interval of 10 seconds, down-time of 60 seconds; __________ as 4; and retries as __________. (Choose the correct set of options to complete the sentence.)
Scenario: An engineer needs to configure a monitor to ensure that each server is tested every 10 seconds and requires that the server pass the test four consecutive times before marking a server as UP. If the test fails, the server should be marked as down for 60 seconds.
To configure the monitor, the engineer should configure an interval of 10 seconds, down-time of 60 seconds; __________ as 4; and retries as __________. (Choose the correct set of options to complete the sentence.)
정답: A
문제2
Which two compression actions could a NetScaler engineer use? (Choose two.)
Which two compression actions could a NetScaler engineer use? (Choose two.)
정답: B,C
문제3
Scenario: A company is using Citrix NetScaler VPX for publishing internal resources using Citrix Access Gateway with Smart Access. Since the number of users has increased the company wants to migrate from Citrix NetScaler VPX to Citrix NetScaler MPX. The engineer is running a parallel installation of the Citrix NetScaler MPX and now needs to transfer the Citrix Access Gateway Universal Licenses from a Citrix NetScaler VPX to a Citrix NetScaler MPX platform.
How should the engineer transfer the Citrix Access Gateway Universal License files from the VPX to the MPX?
Scenario: A company is using Citrix NetScaler VPX for publishing internal resources using Citrix Access Gateway with Smart Access. Since the number of users has increased the company wants to migrate from Citrix NetScaler VPX to Citrix NetScaler MPX. The engineer is running a parallel installation of the Citrix NetScaler MPX and now needs to transfer the Citrix Access Gateway Universal Licenses from a Citrix NetScaler VPX to a Citrix NetScaler MPX platform.
How should the engineer transfer the Citrix Access Gateway Universal License files from the VPX to the MPX?
정답: C
문제4
Scenario: A network engineer has created and bound an UDP-ECV monitor to identify the status of a UDP service. However, no matter what the response is, the service is always marked as UP.
A possible cause of this behavior is that the network engineer __________. (Choose the correct option to complete the sentence.)
Scenario: A network engineer has created and bound an UDP-ECV monitor to identify the status of a UDP service. However, no matter what the response is, the service is always marked as UP.
A possible cause of this behavior is that the network engineer __________. (Choose the correct option to complete the sentence.)
정답: D
문제5
A network engineer has enabled USIP and USNIP and set a unique IP address as the source IP using the proxyIP parameter on an INAT policy.
Which is the correct order of precedence for the IP addresses?
A network engineer has enabled USIP and USNIP and set a unique IP address as the source IP using the proxyIP parameter on an INAT policy.
Which is the correct order of precedence for the IP addresses?
정답: D
문제6
Scenario: Primary NetScaler (NS1) is licensed for 10000 Maximum ICA users and 305 Access Gateway users. Secondary NetScaler (NS2) is licensed for 10000 Maximum ICA users and five Access Gateway users.
From where and which command should a network engineer run to display diagnostics on the licenses?
Scenario: Primary NetScaler (NS1) is licensed for 10000 Maximum ICA users and 305 Access Gateway users. Secondary NetScaler (NS2) is licensed for 10000 Maximum ICA users and five Access Gateway users.
From where and which command should a network engineer run to display diagnostics on the licenses?
정답: D
문제7
How could an engineer configure a monitor to ensure that a server is marked as DOWN if the monitor test is successful?
How could an engineer configure a monitor to ensure that a server is marked as DOWN if the monitor test is successful?
정답: C
문제8
Scenario: A network engineer has installed a NetScaler system into their corporate DMZ and would like to provide access to a web server on the internal LAN. The web server will be accessed by external users through the NetScaler. The firewall administrator has opened the relevant ports required on the external and the internal firewall.
The engineer notices that the virtual server and services representing the web server are down and the internal web server does NOT appear accessible from the NetScaler.
What could be the cause of this?
Scenario: A network engineer has installed a NetScaler system into their corporate DMZ and would like to provide access to a web server on the internal LAN. The web server will be accessed by external users through the NetScaler. The firewall administrator has opened the relevant ports required on the external and the internal firewall.
The engineer notices that the virtual server and services representing the web server are down and the internal web server does NOT appear accessible from the NetScaler.
What could be the cause of this?
정답: C