최신VMware HCI Master Specialist - 5V0-21.20무료샘플문제
문제1
An All-Flash vSAN cluster has 4-nodes with this disk group composition on each host:
* 1 x 800 GB SAS SSD
* 6 x 3.84 TB SATA SSD
An administrator observes that in an All-Flash cluster, the Write
Buffer Free Percentage is consistently low. As a result there is increased latency experienced by the workloads.
Which remediation steps will resolve this issue?
An All-Flash vSAN cluster has 4-nodes with this disk group composition on each host:
* 1 x 800 GB SAS SSD
* 6 x 3.84 TB SATA SSD
An administrator observes that in an All-Flash cluster, the Write
Buffer Free Percentage is consistently low. As a result there is increased latency experienced by the workloads.
Which remediation steps will resolve this issue?
정답: D
문제2
Reference the exhibit.

A university campus has a site topology illustrated in the exhibit. Adjacent connected buildings are connected with a single 40gb layer 3 network with a RTT of 0.6ms as depicted by each line. An architect wants to configure a fault domain in each building.
What would the architect need change in order to implement a fully supported vSAN Cluster?
Reference the exhibit.

A university campus has a site topology illustrated in the exhibit. Adjacent connected buildings are connected with a single 40gb layer 3 network with a RTT of 0.6ms as depicted by each line. An architect wants to configure a fault domain in each building.
What would the architect need change in order to implement a fully supported vSAN Cluster?
정답: C
문제3
A 4-node vSAN cluster has a single disk group per host. An administrator wants to increase the capacity of the vSAN datastore by adding a second disk group to each host in the cluster. The newer drives intended for the second disk group are certified and in compliance with VMware Compatibility Guide (VCG). However, the newer devices procured are of a different make and model than the existing disk group composition.
Considering the scenario, which statement is true?
A 4-node vSAN cluster has a single disk group per host. An administrator wants to increase the capacity of the vSAN datastore by adding a second disk group to each host in the cluster. The newer drives intended for the second disk group are certified and in compliance with VMware Compatibility Guide (VCG). However, the newer devices procured are of a different make and model than the existing disk group composition.
Considering the scenario, which statement is true?
정답: C
문제4
A vSAN disk group contains one cache drive and four capacity drives. A drive that belongs to this disk group has failed. The entire disk group containing the failed drive is offline.
What are two possible reasons the entire disk group is offline? (Choose two.)
A vSAN disk group contains one cache drive and four capacity drives. A drive that belongs to this disk group has failed. The entire disk group containing the failed drive is offline.
What are two possible reasons the entire disk group is offline? (Choose two.)
정답: D,E
문제5
Which is true of the vSAN iSCSI target service?
Which is true of the vSAN iSCSI target service?
정답: A
문제6
Refer to the exhibit.

D18912E1457D5D1DDCBD40AB3BF70D5D
A vSAN Cluster stretched across Data Site 1 and Data Site 2 has a vSAN data network configured with an MTU of 9000. The witness node has been placed in a remote site across a WAN with an MTU of 1500. The vSAN health check, 'vSAN: MTU check (ping with large packet size) , reports a failed ping.
What two actions could resolve the issue? (Choose two.)
Refer to the exhibit.

D18912E1457D5D1DDCBD40AB3BF70D5D
A vSAN Cluster stretched across Data Site 1 and Data Site 2 has a vSAN data network configured with an MTU of 9000. The witness node has been placed in a remote site across a WAN with an MTU of 1500. The vSAN health check, 'vSAN: MTU check (ping with large packet size) , reports a failed ping.
What two actions could resolve the issue? (Choose two.)
정답: A,C
문제7
An administrator needs to perform an urgent maintenance activity on a host that is part of a 3-node vSAN cluster. All the disk groups in the cluster are balanced. They need to choose a maintenance mode option to ensure:
*There is no downtime to any of the virtual machines running in the cluster
*Virtual Machine accessibility is maintained
*No data is left on the host that could possibly cause data loss
Which statement is true if the administrator chooses 'Ensure accessibility' as the maintenance mode option?
An administrator needs to perform an urgent maintenance activity on a host that is part of a 3-node vSAN cluster. All the disk groups in the cluster are balanced. They need to choose a maintenance mode option to ensure:
*There is no downtime to any of the virtual machines running in the cluster
*Virtual Machine accessibility is maintained
*No data is left on the host that could possibly cause data loss
Which statement is true if the administrator chooses 'Ensure accessibility' as the maintenance mode option?
정답: D
문제8
During planned maintenance of a four-node vSAN cluster, an outsourced IT contractor accidentally removed a
2.5" SSD cache disk from one of the vSAN nodes. The storage policy has been configured with FTT=1 RAID
1, and the disk management UI marked the disk group as
Which remediation steps should the administrator select to ensure VMs become compliant with the storage policy as soon as possible?
During planned maintenance of a four-node vSAN cluster, an outsourced IT contractor accidentally removed a
2.5" SSD cache disk from one of the vSAN nodes. The storage policy has been configured with FTT=1 RAID
1, and the disk management UI marked the disk group as
Which remediation steps should the administrator select to ensure VMs become compliant with the storage policy as soon as possible?
정답: D